ERROR on 64-bit Windows machines: The 'Microsoft.Jet.OLEDB.4.0' provider is not registered on the local machine.

Solution Although the 64 Bit version can run 32 Bit software like S&THex, the coexistence of 64 and 32 bit code on the same machine can cause all sorts of seemingly strange issues,
The error is generally due to either of two thing:

• you don’t have Office 2007 Jet drivers installed,
You can download this from the location below:
http://www.microsoft.com/download/en/details.aspx?displaylang=en&id=23734

• Or you are running a 32 bit application in a default x64 environment. Meaning your computer is preventing the application to run properly.
Please check the attachment.

Attachments:
attachment.pdf attachment.pdf